EPA 608 Required Evacuation Levels, Explained

Updated October 26, 2026

Before an appliance is opened for service or disposal, its refrigerant must be recovered down to a required level of vacuum. These levels come up on the Type II and Type III sections of the EPA 608 exam, and they’re easy to mix up. Here’s the table from the regulation (40 CFR 82.156, Table 1), and how to read it.

The table

Levels are in inches of mercury vacuum, except low-pressure appliances, which use millimeters of mercury absolute. The columns depend on when the recovery or recycling equipment was made, not when the appliance was made.

Appliance type Recovery equipment made before Nov 15, 1993 Recovery equipment made on or after Nov 15, 1993
Very high-pressure appliance 0 0
High-pressure, full charge under 200 lb 0 0
High-pressure, full charge of 200 lb or more 4 10
Medium-pressure, full charge under 200 lb 4 10
Medium-pressure, full charge of 200 lb or more 4 15
Low-pressure appliance 25 mm Hg absolute 25 mm Hg absolute

How to read it

  1. Find the pressure class. Most residential and light commercial systems (R-22, R-410A, R-134a) are high-pressure. Centrifugal chillers using R-123 or R-11 are low-pressure.
  2. Check the full charge. The 200-pound line splits large systems from small ones.
  3. Check the recovery equipment’s date. Newer equipment must pull a deeper vacuum on the larger systems.

A useful pattern: newer recovery equipment never has a lower requirement than older equipment, and larger charges never have a lower requirement than smaller ones in the same class.

Small appliances are different

Small appliances (factory-sealed with 5 pounds or less, covered by Type I) don’t use Table 1. With recovery equipment made on or after November 15, 1993, you must recover 90% of the refrigerant if the compressor runs or 80% if it doesn’t. Equipment made before that date must recover 80%. Either way, evacuating to 4 inches of mercury vacuum also meets the requirement.

When a system can’t reach the level

If leaks make it impossible to reach the required level, or reaching it would contaminate the refrigerant, the rules allow recovery to stop at the lowest level that can be reached, within limits. Check the current regulation for the details before relying on this.

Test yourself

  1. A medium-pressure appliance with a 250-pound charge is being opened. The recovery machine was made in 2018. What is the required evacuation level?
  2. A high-pressure appliance with a 250-pound charge is being opened using recovery equipment made in 1990. What is the required evacuation level?
  3. A residential heat pump with 12 pounds of R-410A is being opened using a recovery machine made in 2022. What is the required evacuation level?
  4. Which appliances must be evacuated to 25 mm Hg absolute?

Pass the EPA 608 exam on your first try

  • All 168 questions across Core, Type I, Type II and Type III
  • An explanation for every answer, with the rule or principle behind it
  • Unlimited practice exams per section, scored like the real test (18 of 25 to pass)
Start practicing

EPA608Tests

Full access

Free for 7 days

Then $29 per month

Due today$0.00
  • All 168 questions across Core, Type I, Type II and Type III
  • An explanation for every answer, with the rule or principle behind it
  • Unlimited practice exams per section, scored like the real test (18 of 25 to pass)
  • A full Universal practice exam covering all four sections

Cancel anytime before and you will not be charged.

Secured by Stripe